Validation of a qualitative R5 dip-stick for gluten detection with a new mathematicalstatistical approach
Main Article Content
Keywords
AOAC Appendix N, gluten, R5, qualitative testing, statistical evaluation
Abstract
Specific and sensitive analytical methods are needed to guarantee the safety of gluten-free products for coeliac disease patients at the threshold of 20 mg gluten/kg. Immuno-chromatographic assays, usually available in dip-stick or lateral-flow format, provide rapid qualitative results indicating the presence or absence of gluten. In September 2015, an AOAC expert review panel accepted the qualitative immuno-chromatographic dip-stick system RIDA®QUICK Gliadin as an AOAC Official MethodSM of Analysis First Action 2015.16 for detection of gluten in corn-based food products. One part of the required validation was an international collaborative study with 18 participants who analysed 8 different processed and non-processed samples with different gluten concentrations. Since the official statistical evaluation at AOAC does not provide a calculation of: (1) the concentration and its prediction interval from which a user expects a positive result; and (2) what a negative result means, a new statistical approach was used. The method for modelling the probability of detection (POD) curve and confidence intervals of the LOD95 used a generalised linear mixed effects model together with a 4-parameter sigmoid curve to describe the variability of the POD curves for randomly chosen laboratories beyond those that participated in the study. The results confirmed that, in case of a positive result, a non-processed sample contains a minimum of 4.54 mg gluten/kg (prediction range 3.59-5.74 mg/kg) while a processed sample contains more than 6.29 mg gluten/kg (prediction range 3.88-10.20 mg/kg). Therefore, the method is able to identify negative samples clearly below the threshold of 20 mg gluten/kg which is a prerequisite for gluten testing in food.
References
AOAC International, 2002. AOAC official methods of analysis. Appendix D: guideline for collaborative study procedures to validate characteristics of a method of analysis. AOAC, Gaithersburg, MD, USA.
AOAC International, 2012. Gliadin as a measure of gluten in foods containing wheat, rye, and barley. AOAC official method of analysis 2012.01. AOAC, Gaithersburg, MD, USA.
AOAC International, 2013. AOAC official methods of analysis. Appendix N: ISPAM guidelines for validation of qualitative binary chemistry methods. AOAC, Gaithersburg, MD, USA.
AOAC International, 2015. Gluten in processed and non-processed corn products by qualitative R5 immunochromatographic dip-stick. AOAC official method of analysis 2015.16. AOAC, Gaithersburg, MD, USA.
Bugyi, Z., Török, K., Hajas, L., Adonyi, Z., Popping, B. and Tömösközi, S., 2013. Comparative study of commercially available gluten ELISA kits using an incurred reference material. Quality Assurance and Safety of Crops & Foods 5: 79-87.
European Commission (EC), 2009. Commission regulation (EC) No. 41/2009 of January 20, 2009, concerning the composition and labelling of foodstuffs suitable for people intolerant to gluten. Official Journal of the European Union 16: 3-5.
Food and Agriculture Organisation/World Health Organisation (FAO/WHO), 2013. Codex Standard 234-1999. Recommended methods of analysis and sampling. Codex Alimentarius Commission, FAO/WHO, Rome, Italy.
Food and Agriculture Organisation/World Health Organisation (FAO/WHO), 2015. Codex Standard 118-1979 (Revision 1, Amendment 2). Foods for special dietary use for persons intolerant to gluten. Codex Alimentarius Commission, FAO/WHO, Rome, Italy.
Food and Drug Administration (FDA), 2013. Gluten-free labeling of foods; final rule. Federal Register, Vol. 78, No. 150. Rules and Regulations, pp. 47154-47179. FDA, College Park, MD, USA. Available at: http://tinyurl.com/zks9ssa.
Garcia, E., Llorente, M., Hernando, A., Kieffer, R., Wieser, H. and Méndez, E., 2005. Development of a general procedure for complete extraction of gliadins for heat processed and unheated foods. European Journal of Gastroenterology and Hepatology 17: 529-530.
Health Canada, 2012. Health Canada’s position on gluten-free claims. Health Canada, Ottawa, Ontario, Canada. Available at: http://tinyurl.com/hus37m2.
Immer, U. and Haas-Lauterbach, S., 2012. Gliadin as a measure of gluten in foods containing wheat, rye, and barley – enzyme immunoassay method based on a specific monoclonal antibody to the potentially celiac toxic amino acid prolamin sequences: collaborative study. Journal of AOAC International 95: 1118-1124.
International Organisation for Standardisation (ISO), 1994. ISO 5725-2:1994. Accuracy trueness and precision) of measurement methods and results – Part 2: basic method for the determination of repeatability and reproducibility of a standard measurement method. ISO, Geneva, Switzerland.
International Organisation for Standardisation (ISO), 2015. ISO 13528:2015. Statistical methods for use in proficiency testing by interlaboratory comparison. ISO, Geneva, Switzerland.
International Organisation for Standardisation/International Electrotechnical Commission (ISO/IEC), 2008. JCGM 101 – Evaluation of measurement data – Supplement 1 to the ‘Guide to the expression of uncertainty in measurement’ – Propagation of distributions using Monte Carlo method (guide 98-3-1). ISO, Geneva, Switzerland.
Kahlenberg, F., Sanchez, D., Lachmann, I., Tuckova, L., Tlaskalova, H., Méndez, E. and Mothes, T., 2006. Monoclonal antibody R5 for detection of putative celiac-toxic gliadin peptides. European Food Research and Technology 222: 78-82.
Koehler, P., Schwalb, T., Immer, U., Lacorn, M., Wehling, P. and Don, C., 2013a. AACCI Approved Methods Technical Committee report: collaborative study on the immunochemical determination of intact gluten using an R5 sandwich ELISA. Cereal Foods World 58: 36-40.
Koehler, P., Schwalb, T., Immer, U., Lacorn, M., Wehling, P. and Don, C., 2013b. AACCI Approved Methods Technical Committee report: collaborative study on the immunochemical determination of partially hydrolyzed gluten using an R5 competitive ELISA. Cereal Foods World 58: 154-158.
Lacorn, M. and Weiss, T., 2015. Partially hydrolyzed gluten in fermented cereal-based products by R5 competitive ELISA: collaborative study, first action 2015.05. Journal of AOAC International 98: 1346-1354.
Lionetti, E., Gatti, S., Pulvirenti, A. and Catassi, C., 2015. Celiac disease from a global perspective. Best Practice & Research Clinical Gastroenterology 29: 365-379.
Ludvigsson, J.F., Leffler, D.A., Bai, J.C., Biagi, F., Fasano, A., Green, P.H.R., Hadjivassiliou, M., Kaukinen, K., Kelly, C.P., Leonard, J.N., Lundin, K.E.A., Murray, J.A., Sanders, D.S., Walker, M.M., Zingone, F. and Ciacci, C., 2013. The Oslo definitions for coeliac disease and related terms. Gut 62: 43-52.
Osman, A.A., Uhlig, H.H., Valdes, I., Amin, M., Méndez, E. and Mothes, T., 2001. A monoclonal antibody that recognizes a potential coeliac-toxic repetitive pentapeptide epitope in gliadins. European Journal of Gastroenterology and Hepatology 13: 1189-1193.
Plugis, N.M. and Khosla, C., 2015. Therapeutic approaches for celiac disease. Best Practice & Research Clinical Gastroenterology 29: 503-521.
Scherf, K.A. and Poms, R.E., 2016. Recent advances in analytical methods for tracing gluten. Journal of Cereal Science 67: 112-122.
Scherf, K.A., Koehler, P. and Wieser, H., 2016. Gluten and wheat sensitivities – an overview. Journal of Cereal Science 67: 2-11.
Schuppan, D., Pickert, G., Ashfaq-Khan, M. and Zevallos, V., 2015. Non-celiac wheat sensitivity: differential diagnosis, triggers and implications. Best Practice & Research Clinical Gastroenterology 29: 469-476.
Sicherer, S.H. and Sampson, H.A., 2014. Food allergy: epidemiology, pathogenesis, diagnosis, and treatment. Journal of Allergy and Clinical Immunology 133: 291-307.
Sykes, M., Knaggs, M., Hunter, S., Leach, E., Eaton, C. and Anderson, D., 2014. Some selected discrepancies observed in food chemistry proficiency tests. Quality Assurance and Safety of Crops & Foods 6: 291-297.
Thompson, M., Ellison, S.L.R. and Wood, R., 2006. The international harmonized protocol for the proficiency testing of analytical chemistry laboratories. Pure and Applied Chemistry 78: 145-196.
Thompson, T., 2003. Oats and the gluten-free diet. Journal of the American Dietetic Association 103: 376-379.
Tye-Din, J.A., Stewart, J.A., Dromey, J.A., Beissbarth, T., Van Heel, D.A., Tatham, A., Henderson, K., Mannering, S.I., Gianfrani, C., Jewell, D.P., Hill, A.V., McCluskey, J., Rossjohn, J. and Anderson, R.P, 2010. Comprehensive, quantitative mapping of T cell epitopes in gluten in celiac disease. Science Translational Medicine 2: 41ra51.
Uhlig, S., Niewöhner, L. and Gowik, P., 2011. Can the usual validation standard series for quantitative methods, ISO 5725, be also applied for qualitative methods? Accreditation and Quality Assurance 16: 533-537.
Uhlig, S., Krügener, S. and Gowik, P., 2013. A new profile likelihood confidence interval for the mean probability of detection in collaborative studies of binary test methods. Accreditation and Quality Assurance 18: 367-372.
Uhlig, S., Frost, K., Colson, B., Simon, K., Made, D., Reiting, R., Gowik, P. and Grohmann, L., 2015a. Validation of qualitative PCR methods on the basis of mathematical-statistical modelling of the probability of detection. Accreditation and Quality Assurance 20: 75-83.
Uhlig, S., Simon, K., Frost, K., 2015b. Mathematical-statistical procedure for determining the concentration-dependent probability of detection of qualitative chemical methods on the basis of interlaboratory study data. Available at: http://tinyurl.com/zgqyqly.
Valdes, I., Garcia, E., Llorente, M. and Mendez, E., 2003. Innovative approach to low-level gluten determination in foods using a novel sandwich ELISA protocol. European Journal of Gastroenterology and Hepatology 15: 465-474.